A centrifugal pump curve shows how a particular pump is expected to perform under stated conditions. It is one of the most important documents for checking whether a replacement pump or new selection can meet a system’s requirements. Do not select a pump on horsepower or maximum flow alone. The desired operating point must fall within the manufacturer’s approved range.
The Two Main Axes: Flow and Head
Most pump performance charts place flow on the horizontal axis and head on the vertical axis. In U.S. catalogs, flow is commonly shown in gallons per minute (GPM) and head in feet. Other charts may use cubic meters per hour and meters of head. Confirm units before comparing values.
The curve generally slopes downward as flow increases: for a given pump speed and impeller configuration, higher flow typically corresponds to lower head. A system requires a particular combination of flow and head, and the pump must deliver both together.
What Is Total Dynamic Head?
Total dynamic head, abbreviated TDH, represents the energy the system requires from the pump expressed as an equivalent height of fluid. Static elevation, required discharge pressure, pressure differences and friction losses all contribute. In recirculating systems, the elevation terms can offset differently than in open water transfer, so the system should be analyzed correctly.
As a rough conversion for water near ordinary temperatures, one psi corresponds to approximately 2.31 feet of water head. This conversion depends on the liquid’s specific gravity, and it does not replace a complete piping-loss calculation.
Efficiency and the Best Efficiency Point
Many curves include efficiency contours or a best efficiency point (BEP). Operation near the manufacturer’s intended range can help reduce unnecessary energy consumption and mechanical stress. However, acceptable operating range depends on the pump design, liquid and service. Do not infer a universal safe operating band from a generic chart.
Motor Power and NPSH Requirements
A pump curve may show shaft power, motor loading or horsepower at different operating points. The required motor should be selected for the anticipated range, liquid specific gravity and service conditions. Curves may also indicate net positive suction head required (NPSHr), which must be compared with available NPSH and appropriate margin to reduce cavitation risk.
Worked Selection Approach Without Guessing a Model
- Document the required GPM and calculated TDH for the installation.
- Identify candidate pump families suited to the liquid, temperature and construction requirements.
- Locate the duty point on each candidate manufacturer’s flow-head chart.
- Check whether the point falls within the permitted operating region and consider efficiency.
- Verify motor loading, suction conditions, NPSH, materials, seals and connection dimensions.
- Confirm the exact model and configuration with current manufacturer literature before ordering.
Where to Find Manufacturer Curves
Our Grundfos, Berkeley and Gusher guides link to manufacturer resources for current specifications and drawings. For a broader explanation, see the industrial pump selection guide and irrigation pump sizing guide.
Frequently Asked Questions
Does a pump’s maximum GPM tell me what it will produce?
No. Maximum listed flow may occur at a very different head from your installation. The operating point is the appropriate comparison.
Can I rely on a generic pump curve for an exact replacement?
No. Manufacturer curves are specific to model, hydraulic components, speed and other conditions. The exact configuration matters.
Need help reading a curve? Send us the manufacturer model or pump selection sheet along with your required flow and head.